| Operational modes: |
NMRA/DCC with 14, 28, 128 speed steps |
| |
DCC 2-digit and 4-digit addresses |
| |
Digital Motorola® (old and new), up to 127 speed steps for Motorola® operation |
| |
Analog DC (de-selectable). Analog AC (de-selectable) |
| |
Auto-recognition of operational mode and DCC speed step selection |
| |
Supports Lenz® LG100, Märklin®, Roco® braking selections |
| |
Base-direction bit / Operational status storage |
| |
Intelligent programming mode with Märklin® 6021® |
| Throttle: |
1.1 A continuous load |
| |
Runs DC-, coreless-, and AC motors (with permanent magnet) |
| |
Silent, safe 16 / 32 kHz pulse with frequency regulation of motor |
| |
Overload protection of motor output. Fourth generation load-control (back EMF), de-selectable |
| Function outputs: |
4 outputs, 2 of which for light function |
| |
250mA load per output |
| |
Total current of all function outputs approx. 500 mA |
| |
Free function allocation (function mapping). F0 - F12 (V3.5 F0 - F20) possible |
| |
Outputs short circuit proof |
| Sound features: |
4 (!) independent sound channels |
| |
High performance bridge-tie amplifier, approx. 0.6 Watt |
| |
sound data in memory unit changeable |
| |
Modes for Steam engines, Diesel-hydraulic locos, Diesel-electrical locos, Electro-locos |
| |
8 MBit storage capacity (up to 65 seconds) |
| Loudspeaker: |
Special high-performance speaker, 100 Ohm, 23 mm (0.9 inch) with chamber included |
| Dimensions: |
31 x 15.5 x 6.5mm (1.24 x 0.62 x 0.26 inch) |